
Add to Cart
GE IC200CHS111 I/O terminal's main base 24 Volts DC and 0.5 Amps 32-point 50 box-style terminals
Product information GE IC200CHS111 :
The IC200CHS111 base also has a J1 connector which connects to a cable from the IC200CHS003 connector-style carrier. The IC200CHS111 base also has a J2 connector that can be used to connect to the IC200CHS112 module base, which is the expansion base. An external power supply rated for 24 Volts DC is required for powering the relay coils on the IC200CHS111 base. Terminals A17 and A18 are used for connecting the external power supply.
The user loads need an external power source. A field-replaceable relay is used in the manufacturing of the IC200CHS111 base and has the following specifications: 1 pole, rated loads of 9 Amps at 250 Volts AC, 8 Amps at 30 Volts DC, 6 Amps at 250 Volts AC, or 4 Amps at 30 Volts DC, a peak switching current of 8 Amps, a carry current at 8 Amps, and a minimum permissible load of 100 milliamps at 5 Volts DC
IC200CHS003 | IC200CHS101 | IC200CHS102 | IC200CHS111 | |
Product Name | VersaMax I/O Carrier, Connector Style . A connecting cable (IC200CBL1xxx) and interposing base (IC200CHS011, CHS012, CHS014, CHS015, IC200CHS1xx or IC200CHS2xx) are required . This carrier can be used with all VersaMax I/O modules EXCEPT the following, due to their high isolation requirements: IC200MDL144 Input 240 VAC 4 Point Isolated Module; IC200MDL244 Input 240 VAC 8 Point Isolated Module; IC200MDD850 Mixed 240 VAC Isolated 4 Point / Output Relay 2 .0A Isolated 8 Point Module | Input or Output Interposing Disconnect Style 16 Points . The base has an individual knife-switch disconnect for each signal and common terminal and its corresponding pin on the VersaMax cable connector . Requires IC200CHS003 and a connecting cable IC200CBL1xxx | Expansion Input or Output Interposing Disconnect Style 16 Points . The base has an individual knife-switch disconnect for each signal and common terminal and its corresponding pin on the VersaMax cable connector . Requires a IC200CHS101 main base, can not be directly connected to IC200CHS003 . | I/O Interposing Relay Base (replaceable relays), fused (8 amps, replaceable), 16 points . The relays on these interposing terminals are intended to be controlled with standard 24 VDC 0 .5A VersaMax output modules (IC200MDL740 and IC200MDL750 using IC200CHS003 base and connected by IC200CBL1xxx) . |
Lifecycle Status | Active | Active | Active | Active |
Field Termination Type | ntegrated | Non-Integrated | Non-Integrated | Non-Integrated |
Wiring Termination Style | Connector | Box | Box | Box |
Removable Terminals Connectors | N/A | No | No | No |
Input Voltage | N/A | All discrete modules supported except MDL144, 244, 331, 730 and MDD840, 843, 850 . | All discrete modules supported except MDL144, 244, 331, 730 and MDD840, 843, 850 . | 24 VDC from MDL740 and MDL750 |
Output Voltage | N/A | All discrete modules supported except MDL144, 244, 331, 730 and MDD840, 843, 850 . | All discrete modules supported except MDL144, 244, 331, 730 and MDD840, 843, 850 . | 0-125 VDC, 5/24/125 VDC nominal; 0-265 VAC (47-63 Hz), 120/240 VAC nominal |
Load Current per Point | N/A | N/A | N/A | 8 .0 A for 5-265 VAC, 2 .0 A for 5-30 VDC, 0 .2 A for 31-125 VDC (Replaceable Fuse) |
Protection | N/A | N/A | N/A | Replaceable Fuse |
Points per Common | N/A | N/A | N/A | Isolated Per Point |
Dimensions (W x H x D) | 66 .8 mm (2 .63 in) x 133 .4 mm (5 .25 in) x 70 mm (2 .75 in), not including the height of the DIN-rail | 115 mm (4 .5 in) x 126 mm (4 .95 in) x 65 mm (2 .6 in), not including the height of the DIN-rail | 115 mm (4 .5 in) x 126 mm (4 .95 in) x 65 mm (2 .6 in), not including the height of the DIN-rail | 253 .7 mm (9 .9 in) x 126 mm (4 .95 in) x 73 mm (2 .8 in), not including the height of the DIN-rail |
Cables | Requires a IC200CBL1xxx cable | Requires a IC200CBL1xxx cable | N/A | Requires a IC200CBL1xxx cable |
Module Type: | Genius Bus Controller |
Eff. Data Rate: | N/A |
No. of channels: | 1 |
Drops per Channel: | 30 |
Serial Ports: | 1 (Hand Held Monitor Port) |
Current Required: | 1.3 Amps |
Another module:
IC694MDL230 | 120 VAC Isolated Input (8 Points) |
IC694MDL231 | 240 VAC Isolated Input (8 Points) |
IC694MDL240 | 120 VAC Input (16 Points) |
IC694MDL241 | 24 VAC/VDC Input (16 Points) |
IC694MDL250 | 120 VAC Isolated Input (16 Points) |
IC694MDL260 | 120 VAC Input (32 Points)** |
IC694MDL632 | 125 VDC Input (8 Points) |
IC694MDL634 | 24 VDC Input, Neg/Pos Logic (8 Points) |
IC694MDL645 | 24 VDC Input, Neg/Pos Logic (16 Points) |
IC694MDL646 | 24 VDC Input, Neg/Pos Logic, 1 msec Filter (16 Points) |
IC694MDL654 | 5/12 VDC (TTL) Input, Neg/Pos Logic, (32 Points) |
IC694MDL655 | 24 VDC Input, Neg/Pos Logic, 1 ms, (32 Points) |
IC694MDL660 | 24 VDC Input (32 Points)** |
IC694ACC300 | Input Simulator Module (8 Points) |
HC-UFS13 | HC-UFS23 | HC-UFS73 | HC-UFS43 |
HC-UFS72 | HC-UFS152 | HC-UFS202 | HC-UFS352 |
HC-UFS502 | HC-SFS81 | HF-KP13 | HF-SP102B |
HC-SFS121 | HC-RFS153 | HF-MP13B | HF-SP152B |
HC-SFS201 | HC-RFS203 | HF-MP23B | HF-SP202B |
HC-SFS301 | HC-RFS353 | HF-MP43B | HF-SP352B |
HC-SFS52 | HC-RFS503 | HF-MP73B | HF-SP502B |
HC-SFS102 | HA-LFS11K2 | HF-KP13B | HF-SP51 |
HC-SFS152 | HA-LFS15K2 | HF-KP23B | HF-SP702B |
HC-SFS202 | HA-LFS22K2 | HF-KP43B | HF-SP81 |
HC-SFS352 | HA-LFS11K2B | HF-KP73B | HF-SP121 |
HC-SFS502 | HA-LFS15K2B | HF-SP52 | HF-SP201 |
HC-SFS702 | HA-LFS22K2B | HF-SP102 | HF-SP51B |
HC-SFS53 | HF-MP053 | HF-SP152 | HF-SP81B |
HC-SFS103 | HF-MP13 | HF-SP202 | HF-SP121B |
HC-SFS153 | HF-MP23 | HF-SP352 | HF-SP201B |
HC-SFS203 | HF-MP43 | HF-SP502 | HC-SFS202K |
HC-SFS353 | HF-MP73 | HF-SP702 | HC-SFS201B |
HC-RFS103 | HF-KP053 | HF-SP52B | HC-SFS202B |
SGDM-01AD |
SGDM-01ADA |
SGDM-01ADA/SGDH-01AE+SGMAH-01AAA21 |
SGDM-01ADA+SGMAH-01AAAG761 |
SGDM-01ADA-RY5 |
SGDM-01BDA |
SGDM-02ADA |
SGDM-02ADA/SGDH-02AE+SGMAH-02AAA21 |
SGDM-02ADA+SGMAH-02AAA2C |
SGDM-02ADA+SGMPH-02AAA41 |
SGDM-02ADA+SGMPH-02A1A21 |
SGDM-02AD-R |
SGDM-02BDA |
SGDM-02BDA |
SGDM-02BDA+SGMAH-02BBAB1 |
SGDM-04AC-AD2B |
SGDM-04AC-SD1 |
SGDM-04AC-SD2A |
SGDM-04ACSD2B |
SGDM-04AC-SD2B |
SGDM-04AC-SD2BM |
SGDM-04AC-SD2M |
SGDM-04AD |
Our brand:
1, First, send us the brand, model code/pic of the nameplate, the quantity for inquiry. Then we will send the quote to you. after confirming the model and the quantity, then we will the PI to you.
2, You can transfer by Paypal/ Western Union/Trade assurance/ T/T. When we received the payment, then we will start to prepare the order for you asap.